Masters Thesis Original submission Errata Section 2.1 Design Requirements and Constraints Capacitor values should read "1.8mF, 2mF or 2.4mF" not "1.8uF, 2uF or 2.4uF" Table 3-1 Transformer Core Characteristics Core weight is not 95 lbs, table row should be deleated Section 3.4 Long Pulse Capacitor Bank Capacitor values should read "1.8mF, 2mF or 2.4mF" not "1.8uF, 2uF or 2.4uF" Section 5.4 "resulted in a decrease in 5th harmonic ripple as seen in Figure 5.22" should be "resulted in a decrease in 6th harmonic ripple as seen in Figure 5.22" Figure 5.5 Transformer primary voltage and current at 18.5kHz. Calibration error in "I ph3 pri(x1kA)", amplitude is 1/3 of that displayed Figure 5.6 Transformer primary voltage and current at 20kHz. Calibration error in "I ph3 pri(x1kA)", amplitude is 1/3 of that displayed