Mark 3 Ion Injector


 

Overview:

Test runs of the Mark 3 ion injector

 

Ion Injector Ionization Test 4 (9/23/2005)

Injector immersed in solonoidal magnetic field and successfully ionizes. No extractor electrode was present to help focus ion beam.

 

Ion Injector Filament Test 3 (9/9/2005)

First vacuum test of the mark 3 ion injector. Ionization filament is operational but requires solonoidal field to ionize.

 
 

Useful links:

http://www.fusor.net/ Open Source Fusion Research Consortium.

 

 

 


  Google
WWW http://www.rtftechnologies.org

By attempting to reproduce any experiments or devices listed on this domain in part or in whole, you agree to hold me harmless against any lawsuit or liability.

Copyright © 1998 - 2005 by Andrew Seltzman. All rights reserved.

   